J Am Coll Cardiol Intv, 2010; 3:119-121, doi:10.1016/j.jcin.2009.07.019
© 2010 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Latib, A.
Right arrow Articles by Colombo, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Latib, A.
Right arrow Articles by Colombo, A.
Related Collections
Right arrowRelated Article

Images in Intervention

Post-Implantation Repositioning of the CoreValve Percutaneous Aortic Valve

Azeem Latib, MD*, Iassen Michev, MD*, Jean-Claude Laborde, MD{dagger}, Matteo Montorfano, MD*, Antonio Colombo, MD*,{ddagger},*

* Interventional Cardiology Unit, San Raffaele Scientific Institute, Milan, Italy
{dagger} Cardiology Department, Glenfield Hospital, Leicester, United Kingdom
{ddagger} Interventional Cardiology Unit, EMO-GVM Centro Cuore Columbus, Milan, Italy


A 76-year-old man presented with congestive heart failure on the basis of severe aortic stenosis (AS). Echocardiography confirmed severe calcific AS (mean gradient = 45 mm Hg, peak gradient = 78 mm Hg, aortic valve area = 0.5 cm2, annulus diameter = 25 mm) and globally depressed left ventricular (LV) function (ejection fraction = 30%). He was considered high-risk for surgical valve replacement (Logistic Euroscore = 37.8%) and referred for transfemoral percutaneous aortic valve implantation. A 29-mm self-expanding CoreValve ReValving System (CoreValve Inc., Irvine, California) prosthesis was implanted retrogradely (1). Low suboptimal prosthesis placement was confirmed angiographically (Fig. 1A) and by the presence of hemodynamically severe acute aortic regurgitation (AR) (Fig. 1B) (2). The upper part of the prosthesis was snared (Fig. 2A) with a 30-mm Amplatz GooseNeck (ev3 Inc., Plymouth, Minnesota). Gentle, continuous traction was applied to the prosthesis with the gooseneck for up to 5 min until proximal displacement visually occurred during fluoroscopy (Fig. 2B). Pulling on the prosthesis with jerky and jarring movements should be avoided. Aortography (Fig. 3A) and hemodynamic monitoring (Fig. 3B) confirmed reduction in AR severity. At 6-month follow-up, the patient was asymptomatic, and echocardiography showed recovery of LV function (ejection fraction = 50%) and residual moderate AR.


Figure 1
View larger version (31K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 Aortography and Pressure Tracings Immediately After CoreValve Implantation

(A) Post-implantation aortography documenting low implantation of the CoreValve relative to the aortic annulus (broken line), resulting in severe acute aortic regurgitation. (B) Simultaneous aortic (blue) and left ventricular (red) pressure tracings showing a wide aortic pulse pressure (±85 mm Hg) and equalization of diastolic pressures in late diastole confirming severe aortic regurgitation.

 

Figure 2
View larger version (96K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 Snaring the CoreValve

Fluoroscopic images demonstrating the CoreValve snared with an Amplatz (arrow) GooseNeck (A) and then pulled into a more proximal position (B).

 

Figure 3
View larger version (30K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3 Final Aortography and Pressure Tracings After Repositioning the CoreValve

Final aortography (A) demonstrating a better CoreValve position in relation to the native aortic annulus (broken line) with reduction of the severity of aortic regurgitation, which was confirmed hemodynamically (B) by the finding of a pressure difference in late diastole between the aorta (blue) and left ventricle (red).

 
Low implantation of the CoreValve might result in severe acute AR. This case highlights the importance of hemodynamic assessment of post-procedural AR severity in addition to angiographic evaluation of the paravalvular leak in evaluating the LV tolerance of the regurgitation. The experience with transcatheter aortic valve implantation does not differ from balloon aortic valvuloplasty where grade III AR could be well-tolerated in the presence of LV hypertrophy, whereas grade II AR might be poorly tolerated if LV function is depressed. Repositioning of the CoreValve by snaring is feasible and might reduce the severity of AR. However, this high-risk maneuver should be performed cautiously, because it might result in prosthesis embolization into the ascending aorta. If the operator is concerned about the risk of valve embolization, implanting an Edwards-Sapien valve (Edwards Life Sciences, Irvine, California) or another CoreValve inside the first with the valve-in-valve technique could be considered an alternative procedure.


    Footnotes
 
Dr. Laborde is a consultant for and stockholder of CoreValve, Inc.

* Reprint requests and correspondence: Dr. Antonio Colombo, EMO-GVM Centro Cuore Columbus, 48 Via M. Buonarroti, 20145 Milan, Italy (Email: info{at}emocolumbus.it).

Manuscript received June 11, 2009; revised manuscript received July 21, 2009, accepted July 25, 2009.


    REFERENCES
 Top
 REFERENCES
 

  1. Grube E, Schuler G, Buellesfeld L, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome J Am Coll Cardiol 2007;50:69-76.[Abstract/Free Full Text]
  2. Feldman T, Grossman W. Profiles in valvular heart diseaseIn: Baim DS, editor. Grossman's Cardiac Catheterization, Angiography, and Intervention. 7th edition. Philadelphia, PA: Lippincott Williams and Wilkins; 2006. pp. 638-658.

Related Article

CoreValve Aortic Bioprosthesis: Repositioning Techniques
Manolis Vavuranakis, Dimitrios Vrachatis, and Christodoulos Stefanadis
J. Am. Coll. Cardiol. Intv. 2010 3: 565. [Full Text] [PDF]



This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
M. Vavuranakis, D. Vrachatis, and C. Stefanadis
CoreValve Aortic Bioprosthesis: Repositioning Techniques
J. Am. Coll. Cardiol. Intv., May 1, 2010; 3(5): 565 - 565.
[Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
A. Latib and A. Colombo
Reply
J. Am. Coll. Cardiol. Intv., May 1, 2010; 3(5): 565 - 566.
[Full Text] [PDF]


This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Latib, A.
Right arrow Articles by Colombo, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Latib, A.
Right arrow Articles by Colombo, A.
Related Collections
Right arrowRelated Article

Advertisement
 
   
 
home link current link search link archive link topics link cardiology careers link