Advertisement
top banner image  

topleft corner image     top right corner image
 
ACCF/AHA Clinical Guidelines and Statements

CME logo image
bullet
bullet
bullet
bullet

JACC Homepage JACC Imaging Homepage
Still not a subscriber to JACC Imaging or JACC Interventions?

take action
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet

acc links
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet

jacc interventions image
bullet
bullet
bullet
bullet

     top nav image

     

J Am Coll Cardiol Intv, 2010; 3:122-123, doi:10.1016/j.jcin.2009.08.026
© 2010 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rogers, J. H.
Right arrow Articles by Low, R. I.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Rogers, J. H.
Right arrow Articles by Low, R. I.

Images in Intervention

Bioprosthetic Leaflet Erosion After Percutaneous Mitral Paravalvular Leak Closure

Jason H. Rogers, MD*,*, Allen S. Morris, MD{dagger}, Patricia A. Takeda, MD*, Reginald I. Low, MD*

* Division of Cardiovascular Medicine, University of California Davis Medical Center, Sacramento, California
{dagger} Heart and Vascular Center, Mercy General Hospital, Sacramento, California


Transcatheter closure of prosthetic paravalvular leaks is increasingly performed at experienced centers (1–3). The lack of devices dedicated to paravalvular leak closure has not deterred the off-label use of various occluder devices. These images illustrate the potential complexity of transcatheter paravalvular leak repair with the need for additional occluder placement, and the development of severe leaflet erosion from occluder contact.

A 72-year-old woman who developed acute mitral regurgitation (MR) and cardiogenic shock in December 2006 underwent emergency mitral valve replacement with a #25 Hancock II bioprosthetic valve (Medtronic, Minneapolis, Minnesota), complicated by post-operative adult respiratory distress syndrome, mitral paravalvular leak, hemolytic anemia, and recurrent congestive heart failure. In April 2007, she had transcatheter mitral paravalvular leak closure at an outside facility using an 8-mm Amplatzer Atrial Septal Occluder (AGA Medical Corp., Plymouth, Minnesota), with reduction in the MR as well as improvement in hemolytic anemia and congestive symptoms. In May 2008, she had progressive paravalvular leak adjacent to the original occluder with recurrent congestive heart failure, left pleural effusion, and hemolysis. Because of her high risk for reoperation, she underwent successful percutaneous closure of the remaining lateral paravalvular leak with placement of a 12-mm Amplatzer Vascular Plug II (AGA Medical Corp.). At that time, transesophageal echocardiography showed that the posterior bioprosthetic leaflet was contacting the previously deployed Amplatzer device during diastole, resulting in moderate valvular MR.

Although the patient was initially well-compensated, she developed increasing symptomatic valvular MR and 1 year later underwent open surgical mitral valve replacement with a #27 Carpentier-Edwards Magna Thermo FX pericardial valve (Edwards Lifesciences, Irvine, California), as well as bioprosthetic aortic valve replacement for moderate central aortic insufficiency. Intraoperative inspection of the bioprosthetic mitral valve revealed the occluder devices in place, but with significant fractures seen in the first occluder, which was contacting the posterior leaflet, resulting in severe leaflet erosion and perforation (Fig. 1). The patient's recovery was uneventful.


Figure 1
View larger version:
[in this window]
[in a new window]
[Download PPT slide]
 


Click on image to view video


Click on image to view video

Figure 1 Bioprosthetic Mitral Valvular Leaflet Erosion Following Transcatheter Paravalvular Leak Closure

(A) Fluoroscopic view of adjacent Amplatzer Atrial Septal Occluder (ASO, *) and Amplatzer Vascular Plug II (AVP, **) occluding the mitral paravalvular leak. (B) Transesophageal echocardiographic images demonstrating leaflet perforation (arrow) from the ASO (*), which protrudes in the left ventricular (LV) cavity. Note severe regurgitant jet through the leaflet. (C) Left atrial (LA) intraoperative view of adjacent occluder devices and valve. The ASO (*) and AVP (**) are shown, as well as the eroded posterolateral leaflet (arrow). The ventricular aspect of the ASO is visible through the defect in the leaflet. (D) Excised valve and devices, showing relative sizes. (E) Close-up of ventricular aspect of excised valve showing large erosion defect in the posterior leaflet (arrow). (F) ASO with LA disc (*) and deformed ventricular disc with multiple wire fractures (small arrows). Also see Online Videos 1 and 2.

 

    Appendix
 Top
 Appendix
 REFERENCES
 
For Videos 1 and 2 and their accompanying legends, please see the online version of this article.

* Reprint requests and correspondence: Dr. Jason H. Rogers, Division of Cardiovascular Medicine, University of California Davis Medical Center, 4860 Y Street, Suite 2820, Sacramento, California 95817 (Email: jason.rogers{at}ucdmc.ucdavis.edu).

Manuscript received July 16, 2009; revised manuscript received August 17, 2009, accepted August 20, 2009.


    REFERENCES
 Top
 Appendix
 REFERENCES
 

  1. Kim MS, Casserly IP, Garcia JA, Klein AJ, Salcedo EE, Carroll JD. Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet? J Am Coll Cardiol Intv 2009;2:81-90.[Abstract/Free Full Text]
  2. Pate GE, Al Zubaidi A, Chandavimol M, Thompson CR, Munt BI, Webb JG. Percutaneous closure of prosthetic paravalvular leaks: case series and review Catheter Cardiovasc Interv 2006;68:528-533.[CrossRef][Web of Science][Medline]
  3. Sorajja P, Cabalka AK, Hagler DJ, et al. Successful percutaneous repair of perivalvular prosthetic regurgitation Catheter Cardiovasc Interv 2007;70:815-823.[CrossRef][Web of Science][Medline]




This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rogers, J. H.
Right arrow Articles by Low, R. I.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Rogers, J. H.
Right arrow Articles by Low, R. I.

Advertisement
 
   
 
home link current link search link archive link topics link cardiology careers link