J Am Coll Cardiol Intv, 2009; 2:977-985, doi:10.1016/j.jcin.2009.07.007
© 2009 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meredith, I. T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Meredith, I. T.
Related Collections
Right arrowRelated Article

Clinical Research

Clinical and Angiographic Results With the Next-Generation Resolute Stent System

A Prospective, Multicenter, First-in-Human Trial

Ian T. Meredith, MBBS, PhD*,*, Stephen Worthley, MBBS{dagger}, Robert Whitbourn, MBBS{ddagger}, Darren L. Walters, MBBS§, Dougal McClean, MD||, Mark Horrigan, MBBS, Jeffrey J. Popma, MD#, Donald E. Cutlip, MD**, Ann DePaoli, DVM{dagger}{dagger}, Manuela Negoita, MD{dagger}{dagger}, Peter J. Fitzgerald, MD{ddagger}{ddagger} for the RESOLUTE Investigators

* Monash Heart Monash Medical Centre and University, Melbourne, Australia
{dagger} Royal Adelaide Hospital, Adelaide, Australia
{ddagger} St. Vincent's Hospital, Melbourne, Australia
§ Prince Charles Hospital, Brisbane, Australia
|| Christchurch Hospital, Christchurch, New Zealand
The Austin Health Medical Centre, Melbourne, Australia
# Beth Israel Deaconess Medical Center, Boston, Massachusetts
** Harvard Clinical Research Institute, Boston, Massachusetts
{dagger}{dagger} Medtronic CardioVascular, Santa Rosa, California
{ddagger}{ddagger} Stanford University Hospital, Palo Alto, California


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
Objectives: The RESOLUTE trial examined the safety and efficacy of a next-generation zotarolimus-eluting coronary stent, Resolute (Medtronic CardioVascular Inc., Santa Rosa, California).

Background: Revascularization benefits associated with current drug-eluting stents are often diminished in the presence of complex coronary lesions and in certain patient cohorts. Resolute uses a new proprietary polymer coating that extends the duration of drug delivery to match the longer healing duration often experienced in more complex cases.

Methods: The RESOLUTE trial was a prospective, nonrandomized, multicenter study of the Resolute stent in 139 patients with de novo coronary lesions with reference vessel diameters ≥2.5 and ≤3.5 mm and lesion length ≥14 and ≤27 mm. The primary end point was 9-month in-stent late lumen loss by quantitative coronary angiography. Secondary end points included major adverse cardiac events (MACE) at 30 days, 6, 9, and 12 months; acute device, lesion, and procedure success; and 9-month target vessel failure (TVF), target lesion revascularization (TLR), stent thrombosis, neointimal hyperplastic (NIH) volume, and percent NIH volume obstruction.

Results: The 9-month in-stent late lumen loss was 0.22 ± 0.27 mm. Cumulative MACE were 4.3%, 4.3%, 7.2%, and 8.7% at 30 days, 6, 9, and 12 months, respectively. Acute lesion, procedure, and device success rates were 100.0%, 95.7%, and 99.3%, respectively. At 9 months, TLR was 0.0%, TVF was 6.5%, stent thrombosis was 0.0%, NIH volume was 6.55 ± 7.83 mm3, and percent NIH volume obstruction was 3.73 ± 4.05%.

Conclusions: In this feasibility study, the Resolute stent demonstrated low in-stent late lumen loss, minimal neointimal hyperplastic ingrowth, low TLR, no stent thrombosis, and acceptable TVF and MACE. (The RESOLUTE Clinical Trial; NCT00248079)

Key Words: coronary artery disease • drug-eluting stents • zotarolimus

Abbreviations and Acronyms
  ARC = Academic Research Consortium
  BMS = bare-metal stent(s)
  DES = drug-eluting stent(s)
  IVUS = intravascular ultrasound
  LIA = late incomplete apposition
  MACE = major adverse cardiac events
  MI = myocardial infarction
  MLD = minimal lumen diameter
  NIH = neointimal hyperplasia
  QCA = quantitative coronary angiography
  TLR = target lesion revascularization
  TVF = target vessel failure
  TVR = target vessel revascularization
  ZES = zotarolimus-eluting stent(s)


Drug-eluting stents (DES) have significantly reduced the rates of clinical and angiographic restenosis compared with bare-metal stents (BMS) in patients undergoing percutaneous coronary interventions for symptomatic coronary artery disease (1–3). However, the revascularization benefits with DES are often diminished in the presence of high-risk lesions and in certain patient cohorts, such as patients with diabetes (4), patients with diffuse or multivessel disease, patients with chronic renal failure (5), patients with left main disease or ostial disease, or patients who present with chronic total occlusions (6).

The Resolute (Medtronic CardioVascular, Inc., Santa Rosa, California) is a next-generation zotarolimus-eluting stent (ZES) system designed to match the efficacy and safety of the Endeavor stent (Medtronic) while improving clinical outcomes in more complex lesion subsets. The Resolute stent consists of the antiproliferative agent zotarolimus and the low-profile, thin-strut Driver (Medtronic) BMS platform, like the Endeavor stent. However, instead of the phosphorylcholine coating of the Endeavor stent, the Resolute stent employs the BioLinx tri-polymer coating to extend drug elution to match the potentially delayed arterial healing times associated with treatment of more complex lesions and to combat the greater sustained stimulus to the proliferative response in these more difficult patients (7).

The objectives of this first-in-human, prospective, nonrandomized, multicenter study of the Resolute stent system were to: 1) assess the early feasibility and safety of implanting the Resolute stent system in human coronary arteries on the basis of acute success rates and incidence of major adverse cardiac events (MACE) at 30 days; and 2) assess the medium-term safety and efficacy of the Resolute stent system on the basis of in-segment late lumen loss at 9 months and the cumulative incidence of MACE at 6, 9, and 12 months.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
Study overview and patient population.   The RESOLUTE trial was a prospective, multicenter, nonrandomized, single-arm study of the use of the Resolute stent to treat 139 consecutive patients with symptomatic ischemic heart disease attributable to native coronary artery stenosis amenable to treatment by percutaneous stenting. Of the 139 consecutive patients enrolled, the first 30 consented to a 4-month follow-up evaluation by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) measurements, and the next 100 consented to a 9-month follow-up evaluation by QCA and IVUS. Nine additional patients were enrolled as part of a pharmacokinetic substudy and were not required to undergo baseline IVUS or 4-month or 9-month angiographic and IVUS evaluation (Fig. 1). The results of the 4-month, 30-patient cohort were reported previously (8).


Figure 1
View larger version (21K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 Patient Disposition

Of the 139 consecutive patients enrolled in the RESOLUTE trial, the first 30 consented to a 4-month follow-up with quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), and the next 100 consented to a 9-month follow-up with QCA and IVUS. Nine additional patients were enrolled as part of a pharmacokinetic (PK) substudy and were not required to undergo baseline IVUS or 4- or 9-month angiographic and IVUS evaluation. A total of 135 patients completed 12-month clinical follow-up. *3 patients died, and 1 was lost to follow-up.

 
The study was conducted according to the Declaration of Helsinki, and local ethics committees approved the study protocol. All patients provided signed, written consent. Individuals eligible for enrollment were consecutive patients 18 years of age or older with symptomatic ischemic heart disease due to de novo stenotic lesions (>50% angiographic diameter stenosis by visual estimate) in native coronary arteries. The target lesion had to be a single de novo lesion in a native coronary artery with a reference vessel diameter ≥2.5 and ≤3.5 mm, a lesion length ≥14 and ≤27 mm, and a Thrombolysis In Myocardial Infarction flow grade ≥2. Patients were excluded if they experienced a recent (<72 h) myocardial infarction (MI), underwent prior stent placement within the target vessel or any other vessel within 30 days before the index procedure, or had any general contraindication to the revascularization procedure and routine dual antiplatelet therapies. Principal angiographic exclusion criteria were: left main or ostial target lesion; severe calcification by angiography; bifurcation lesion; location of the target lesion at a 45° bend; significant stenosis >50% proximal or distal to the target lesion that might require revascularization or impede runoff; involvement of a side branch >2.0 mm in diameter; or left ventricular ejection fraction <30%.

Device description.   The Resolute stent is similar to the Endeavor stent except that the biomimetic phosphorylcholine drug carrier of the Endeavor stent is replaced with the BioLinx polymer system. The BioLinx polymer system (7) consists of a blend of 3 different polymers: 1) the hydrophobic C10 polymer, which aids in the control of drug release; 2) the hydrophilic C19 polymer, which supports biocompatibility; and 3) polyvinyl pyrrolidinone, which increases the initial drug burst and enhances the elution rate (9). Like the phosphorylcholine coating of the Endeavor stent, the new polymer coating of the Resolute is biocompatible. The hydrophilic surface mimics the body's biological chemistry, thereby reducing the risk of an inflammatory response.

Autopsy examinations have identified polymer hypersensitivity as 1 possible risk factor contributing to stent-thrombosis deaths associated with first-generation sirolimus- and paclitaxel-eluting stents (10,11). In a study comparing the Resolute stent, including the new polymer coating, with the Driver BMS in porcine coronary arteries, there were no significant inflammatory differences between the cohorts at 28 days, and endothelialization in the presence of the BioLinx polymer was rapid and complete (12). In another study comparing the Endeavor stent and the Resolute stent in porcine coronary arteries, biocompatibility was similar out to 180 days (12).

The BioLinx coating of the Resolute stent enables finer control of the rate of drug elution. Although the zotarolimus dose is similar for the Endeavor stent and the Resolute stent, drug elution is slower with the Resolute stent, resulting in an extended duration of drug availability to the arterial tissue. In the porcine model, the Resolute stent elutes 85% of its zotarolimus content during the first 60 days after procedure, and the remainder of the drug is completely eluted by 180 days (Fig. 2) (12).


Figure 2
View larger version (13K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 The In Vivo Elution of the Resolute Zotarolimus-Eluting Stent System

The Resolute stent elutes >85% of zotarolimus during the first 60 days after procedure, and the remainder of the drug is completely eluted at 180 days. Reprinted with permission from Meredith et al. (8). LOQ = level of quantification.

 
Interventional procedure and adjunctive drug therapies.   Twelve sites in Australia and New Zealand participated in this study. Stents were deployed according to standard procedure. Heparin was administered to maintain an activated clotting time ≥250 s or between 200 and 250 s if a glycoprotein IIb/IIIa receptor inhibitor was administered. Patients received aspirin (at least 75 mg daily, within 24 h before the procedure and continued indefinitely after the procedure) and clopidogrel (≥300-mg loading dose within 24 h before the procedure and then 75 mg daily for a minimum of 6 months after the procedure). Pre-dilation was mandatory and undertaken with a balloon length shorter than the stent. Post-dilation, if required, was also performed with a balloon length less than or equal that of the stent. Resolute stents were available in diameters ranging from 2.5 to 3.5 mm and in lengths from 8 to 30 mm.

Data management and core laboratories.   Conduct of the trial was monitored by a contract research organization (Pacific Clinical Research Group, New South Wales, Australia). All data were submitted to a central data coordinating facility (Cardiovascular Data Analysis Center, Harvard Clinical Research Institute, Boston, Massachusetts). All events were adjudicated by an independent clinical events committee managed by the Harvard Clinical Research Institute.

Coronary angiograms performed at baseline and at 4- and 9-month follow-up were reviewed by an independent angiographic core laboratory (Brigham and Women's Angiographic Core Laboratory, Boston, Massachusetts). Standard image acquisition was performed with 2 or more angiographic projections of the stenosis before and after stent placement. Qualitative analysis was performed on the basis of the modified American College of Cardiology/American Heart Association classification (13). Quantitative angiographic analysis was performed on the basis of a validated automated edge detection algorithm (Medis CMS, Leiden, the Netherlands) (14). Frames were selected for analysis in the 2 "sharpest and tightest" views that minimized foreshortening and vessel overlap. The contrast-filled injection catheter was used as the calibration source. The IVUS images were also examined by an independent core laboratory (Cardiovascular Core Analysis Laboratory, Stanford University, Palo Alto, California) (15,16). For both coronary angiograms and IVUS images, quantitative analysis was performed to evaluate the in-stent region (bordered by the stent margins) as well as the in-segment region (in-stent region plus 5-mm margins proximal and distal to the stent).

Study end points and definitions.   The primary efficacy end point, in-stent late lumen loss, was examined by QCA at the 9-month follow-up. Secondary angiographic and IVUS efficacy end points included in-segment late lumen loss at 9 months, angiographic binary restenosis (both in-stent and in-segment) at 9 months, and percent volume obstruction assessed by IVUS at 9 months. A tertiary analysis was also performed comparing the 9-month in-stent late lumen loss in the RESOLUTE trial with the historical ENDEAVOR II trial matched patient subset (patients who received the Endeavor ZES).

Late lumen loss was defined as the difference between the minimal lumen diameter (MLD) at the completion of the stenting procedure and the MLD measured at angiographic follow-up. Angiographic binary restenosis was defined as a stenosis ≥50% of the lumen diameter of the target lesion (determined by the angiographic core laboratory). Reference vessel diameter was defined as the average of the normal segments within 10 mm proximal and distal to the target lesion from 2 orthogonal views with QCA. Percent diameter stenosis was defined as: (1 – [MLD/reference vessel diameter] x 100), and acute gain was defined as the MLD immediately after the procedure minus the MLD before the procedure. Neointimal hyperplastic (NIH) area was computed as stent minus lumen area. Volumetric analysis was performed by means of Simpson's method for the entire stented segment. In detailed analysis, NIH growth was analyzed as NIH area/volume divided by the corresponding stent area/volume to adjust for the different stent sizes. The entire in-stent NIH growth was evaluated as percent NIH volume (i.e., NIH volume x 100/stent volume). The most severe luminal obstruction by NIH growth within the stent segment was determined as the maximum of percent NIH area (i.e., NIH area x 100/stent area).

Secondary clinical safety and efficacy end points included MACE (defined as the composite of all-cause death, MI, and clinically driven target lesion revascularization [TLR]); the individual components of the composite end point in-hospital, at 30 days and at 6, 9, and 12 months; stent thrombosis (acute, <1 day; subacute, 1 to 30 days; and late, >30 days); clinically driven target vessel revascularization (TVR) at 9 months; and target vessel failure (TVF) (composite of cardiovascular death, MI, and clinically driven TVR) at 9 months.

Death was defined as the occurrence of death from any cause during the study period. Myocardial infarction was defined as a creatine kinase elevation ≥2 times above the upper limit of normal with any associated elevation in the myocardial band or the development of new pathologic Q waves in 2 contiguous electrocardiographic leads. Target lesion revascularization was defined as any percutaneous intervention or bypass surgery performed on the index target lesion at any time after the index procedure. Target vessel revascularization was defined as any percutaneous intervention or bypass surgery performed on the index target vessel at any time after the index procedure. Stent thrombosis was defined as an acute coronary syndrome with angiographic documentation of vessel occlusion or thrombus within or adjacent to a previously stented segment, consistent with the ENDEAVOR I to IV clinical studies (17–21); in the absence of angiography, stent thrombosis could be confirmed by acute MI in the distribution of the treated vessel or death resulting from cardiac causes within 30 days. All stent thrombosis events were also adjudicated according to Academic Research Consortium (ARC) criteria (22).

Acute lesion success was defined as achievement of a target lesion percent diameter stenosis <50% by any method; device success was defined as acute lesion success with only the Resolute stent; and procedure success was defined as device success without in-hospital MACE.

Statistical methods.   The main objective of the RESOLUTE trial was to demonstrate the acute safety of the Resolute ZES and gather information on the mid- and long-term safety and efficacy of the device. Therefore the trial was designed to minimize the number of subjects exposed to the device while still providing enough information on safety and efficacy. A sample size of 139 subjects was deemed sufficient to provide reasonable confidence in the estimates of safety and efficacy generated by this study. All analyses were made on an intention-to-treat basis, defined as the set of 139 patients with qualifying stenosis in which treatment with the Resolute stent system was intended (i.e., all patients in whom a guidewire was used to initiate the procedure). Angiographic and IVUS data, collected at baseline and at 4- or 9-month follow-up, were analyzed on all RESOLUTE patients with technically successful paired data for the pairwise comparisons. Categorical variables were tested with contingency tables analyses (exact or chi-square approximations), and continuous variables were tested with unpaired Student t test or Wilcoxon rank sum test, depending on variable distribution. Comparisons between matched cohorts of the RESOLUTE and ENDEAVOR II studies were presented with differences (with 95% confidence intervals) and p values. All statistical tests were 2-sided, and a p value <0.05 was considered statistically significant.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
Patient characteristics.   Baseline clinical characteristics for all 139 patients are reported in Table 1. The age, sex-distribution, and risk-factor profiles of the study patients were consistent with those of a population of patients presenting with ischemic symptoms due to a discrete de novo lesion in a single native coronary artery (23).


View this table:
[in this window]
[in a new window]

 
Table 1 Patient Characteristics (n = 139)
 
Procedural outcomes.   Procedural and lesion characteristics are summarized in Table 2. Of the 139 patients enrolled, there were 140 lesions (in 1 patient, the treated lesion was later adjudicated by the angiographic core laboratory as being 2 lesions in the same vessel.). The mean lesion length was 15.61 ± 6.13 mm. The acute lesion success rate was 100.0% (140 of 140), the procedure success rate was 95.7% (133 of 139), and the device success rate was 99.3% (139 of 140).


View this table:
[in this window]
[in a new window]

 
Table 2 Procedural and Lesion Characteristics
 
Angiographic and IVUS outcomes.   The 4- and 9-month QCA results are presented in Table 3. At 4 months, the in-stent late lumen loss was 0.12 ± 0.26 mm, the in-segment late lumen loss was 0.05 ± 0.20 mm, and both the in-stent and -segment binary angiographic restenosis were 0.0%.


View this table:
[in this window]
[in a new window]

 
Table 3 Angiographic Results at 4 and 9 Months
 
At 9 months, the in-stent late lumen loss was 0.22 ± 0.27 mm, and in-segment late lumen loss was 0.12 ± 0.27 mm. There were no significant edge effects. At 9 months, in-stent binary restenosis was 1.0%, and in-segment binary restenosis was 2.1%. Compared with the matched cohort from the ENDEAVOR II study (18), the 9-month in-stent late lumen loss with the Resolute stent was significantly less than that seen with the Endeavor stent (0.62 ± 0.46 mm) (difference = –0.39 mm [95% confidence interval: –0.49 to –0.29], p < 0.001).

The 4- and 9-month IVUS results are presented in Table 4. The mean external elastic membrane volume after procedure at 4 and 9 months were similar, indicating that there was no significant positive or negative remodeling overall. Moreover, the stent volume was similar, indicating no stent recoil. The NIH volume was 0.55 ± 1.38 mm3 after procedure, 3.72 ± 4.21 mm3 at 4 months, and 6.55 ± 7.83 mm3 at 9 months. The percent NIH volume obstruction was 2.23 ± 2.43% at 4 months and 3.73 ± 4.05% at 9 months. Six late incomplete appositions (LIA) (involving 1 or more stent struts) were identified, with 2 involving the edge of the stent and 4 involving the body of the stent. One LIA was associated with positive vessel remodeling (external elastic membrane volume: after procedure = 231.7 mm3; at follow-up = 258.9 mm3; percent difference = 11.7%), whereas the other 5 were modest.


View this table:
[in this window]
[in a new window]

 
Table 4 Intravascular Ultrasound Results at 4 and 9 Months
 
Clinical outcomes.   Table 5 summarizes the cumulative composite and component MACE at 30 days, 6, 9, and 12 months. Figure 3 presents the cumulative incidence of TLR and cardiac death and MI through 12 months and dual antiplatelet therapy at 30 days, 6, 9, and 12 months. The 30-day incidence of MACE was 4.3%, which consisted entirely of 6 cases of periprocedural non–Q-wave MI. Of these 6 events, 5 occurred at the time of the index procedure and were due to factors that occurred before study stent implantation. All 6 cases of periprocedural non–Q-wave MI resolved uneventfully.


View this table:
[in this window]
[in a new window]

 
Table 5 Cumulative Composite of MACE at 30 Days, 6, 9, and 12 Months
 

Figure 3
View larger version (9K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3 Cumulative Incidence of TLR and Cardiac Death and MI Through 12 Months and DAPT at 30 Days, 6, 9, and 12 Months

Kaplan-Meier graph depicting the cumulative incidence of cardiac death and myocardial infarction (MI) (solid blue line) and target lesion revascularization (TLR) (dashed orange line) to 12 months. Also presented is the percentage of patients receiving dual antiplatelet therapy (DAPT) (aspirin + clopidogrel or ticlopidine) at discrete time points (30, 180, 270, and 360 days).

 
From 30 days to 9 months, 4 additional events occurred—1 cardiac death, 1 noncardiac death, and 2 iatrogenic non–Q wave MIs precipitated by protocol mandated follow-up—resulting in a 9-month cumulative MACE of 7.2% (10 of 139).

From 9 months to 12 months there was 1 additional noncardiac death due to cancer and 1 TLR, resulting in a 12-month cumulative incidence of MACE of 8.7% (12 of 138). The cumulative incidence of TVF at 9 months was 6.5%; at 12 months it was 7.2%. According to protocol-specified definitions, there were no cases of stent thrombosis through 12 months; however, there was 1 case of possible stent thrombosis with ARC criteria (22).


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
In this first-in-human feasibility study, RESOLUTE, we report the safety and efficacy of the Resolute stent, which consists of the low-profile, thin-strut Driver BMS platform, the antiproliferative agent zotarolimus, and the new proprietary biomimetic BioLinx polymer system. Overall, the Resolute stent demonstrated a safety profile comparable to that of the Endeavor stent (17–20). In the RESOLUTE trial, patient, vessel, and lesion characteristics were similar to previous first-in-human DES studies (17,24–27), although the average lesion length was longer (15.61 ± 6.13 mm) and there were more B2/C lesions (81%) in the present study. Despite the longer lesion length and complexity, the Resolute achieved high acute lesion, procedure, and device success rates. Cumulative MACE rates were low and largely driven by an unexpectedly high number of procedural events unrelated to the study stent, including 1 protocol violation (elevated cardiac enzymes at enrollment), 4 sidebranch occlusion events at the time of balloon pre-dilation, and 2 iatrogenic events related to the IVUS 9-month follow-up. There was a low rate of TVF, no protocol-defined or ARC definite or probable early or late stent thromboses, and only 1 patient required a TLR through 12 months.

On the basis of the study's QCA and IVUS results, the Resolute stent also showed promising efficacy. The primary end point of this trial, the in-stent late lumen loss at 9 months, was 0.22 ± 0.27 mm, which was significantly less than that seen in the matched Endeavor stent cohort of the ENDEAVOR II study (18). The low level of late loss with the Resolute stent translated into a modest level of binary in-stent restenosis (1.0%) and binary in-segment restenosis (2.1%). Mauri et al (28) previously described the curvilinear relationship between late lumen loss and angiographic binary restenosis and predicted a restenosis rate in a population with a mean reference vessel diameter of 2.79 mm and a mean post-procedure MLD of 2.68 mm. In our study, the mean pre-procedure reference vessel diameter was 2.81 mm and the mean post-procedure MLD was 2.76 mm. Extrapolating from this relationship, a late lumen loss of 0.22 mm would correlate with approximately 1.0% to 2.0% in-stent binary restenosis, which is indeed what we observed in this study. These data support the BioLinx design hypothesis that extending the duration of zotarolimus release results in lower late loss.

The 9-month IVUS results confirmed that the mean external elastic membrane volume was well-preserved, indicating there was no overt positive remodeling of the vessels overall. The stent volume was also well-conserved, indicating that there was little or no recoil of the stent. In addition, the NIH volume and percent NIH volume obstruction were quite low, consistent with the potent antiproliferative effect of zotarolimus. There were, however, 6 LIA noted at the 9-month IVUS follow-up. Two were edge-related, and 4 were in the body of the stent. This is in contrast to the Endeavor I, II, and III trials (which included IVUS follow-up) where, in total, only 1 LIA was observed. This shows that the mean late loss and mean and SD of the late loss distribution seem to shift to the left. In doing so, one would expect to observe some degree of negative late loss and positive remodeling resulting in additional LIA by IVUS. Of the 6 observed LIA in the RESOLUTE trial, only 1 required a TLR (at 280 days). Although there have been several small studies that show a relationship between LIA and late stent thrombosis, it has not been conclusively demonstrated (29).


    Conclusions
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
The results of the RESOLUTE feasibility study found the Resolute stent safe and effective, with high acute lesion, procedure, and device deployment success rates. Treatment of patients with symptomatic ischemic heart disease and single-vessel de novo lesions by means of the Resolute stent system resulted in sustained clinical effectiveness and very modest changes in vessel lumen dimensions up to 9 months and minimal late lumen loss. This translated into very low TLR, acceptable TVF and MACE rates, and no cases of protocol-defined or ARC definite or probable stent thrombosis. Three controlled studies (RESOLUTE US, RESOLUTE ALL COMERS, and RESOLUTE INTERNATIONAL) are currently underway to confirm the RESOLUTE study's results in more complex lesion cohorts.


    Appendix
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 
For a list of the RESOLUTE stent trial investigators, please see the online version of this article.


    Acknowledgments
 
The authors thank Janice Hoettels, PA-C, and Jane Moore, MS for their assistance in the preparation of this manuscript.


    Footnotes
 
This study was supported by Medtronic CardioVascular, Inc.

* Reprint requests and correspondence: Dr. Ian T. Meredith, Monash HEART and Monash University, Monash Medical Centre, 246 Clayton Road, Melbourne, Victoria, Australia (Email: ian.meredith{at}med.monash.edu.au).

Manuscript received March 20, 2009; revised manuscript received July 17, 2009, accepted July 25, 2009.


    REFERENCES
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 Appendix
 REFERENCES
 

  1. Katritsis DG, Karvouni E, Ioannidis JP. Meta-analysis comparing drug-eluting stents with bare metal stents Am J Cardiol 2005;95:640-643.[CrossRef][Web of Science][Medline]
  2. Stone GW, Moses JW, Ellis SG, et al. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents N Engl J Med 2007;356:998-1008.[CrossRef][Medline]
  3. Kastrati A, Mehilli J, Pache J, et al. Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents N Engl J Med 2007;356:1030-1039.[CrossRef][Medline]
  4. Stankovic G, Cosgrave J, Chieffo A, et al. Impact of sirolimus-eluting and paclitaxel-eluting stents on outcome in patients with diabetes mellitus and stenting in more than one coronary artery Am J Cardiol 2006;98:362-366.[CrossRef][Web of Science][Medline]
  5. Kuchulakanti PK, Torguson R, Chu WW, et al. Impact of chronic renal insufficiency on clinical outcomes in patients undergoing percutaneous coronary intervention with sirolimus-eluting stents versus bare metal stents Am J Cardiol 2006;97:792-797.[CrossRef][Web of Science][Medline]
  6. Abbas AE, Brewington SD, Dixon SR, Boura J, Grines CL, O'Neill WW. Success, safety, and mechanisms of failure of percutaneous coronary intervention for occlusive non-drug-eluting in-stent restenosis versus native artery total occlusion Am J Cardiol 2005;95:1462-1466.[CrossRef][Web of Science][Medline]
  7. Udipi K, Melder RJ, Chen M, et al. The next generation Endeavor Resolute stent: role of the BioLinx polymer system EuroInterv 2007;3:137-139.
  8. Meredith IT, Worthley S, Whitbourn R, et al. The next generation Endeavor Resolute stent: 4-month clinical and angiographic results from the Endeavor Resolute first-in-man trial EuroInterv 2007;3:50-53.
  9. Udipi K, Chen M, Cheng P, et al. Development of a novel biocompatible polymer system for extended drug release in a next-generation drug-eluting stent J Biomed Mater Res A 2008;85:1064-1071.[Medline]
  10. Joner M, Finn AV, Farb A, et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk J Am Coll Cardiol 2006;48:193-202.[Abstract/Free Full Text]
  11. Luscher TF, Steffel J, Eberli FR, et al. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications Circulation 2007;115:1051-1058.[Abstract/Free Full Text]
  12. Carter A, Melder RJ, Udipi K, Ozdil F, Virmani R, Wilcox JN. In vivo performance of a novel co-polymer system for extended release of zotarolimus in a next generation drug-eluting stent [TCT abstract 34] Am J Cardiol 2006;98(Suppl 1)16M.
  13. Ellis SG, Vandormael MG, Cowley MJ, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Multivessel Angioplasty Prognosis Study Group. Circulation 1990;82:1193-1202.[Abstract/Free Full Text]
  14. van der Zwet PM, Reiber JH. A new approach for the quantification of complex lesion morphology: the gradient field transform; basic principles and validation results J Am Coll Cardiol 1994;24:216-224.[Abstract]
  15. Sonoda S, Morino Y, Ako J, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the SIRIUS trial J Am Coll Cardiol 2004;43:1959-1963.[Abstract/Free Full Text]
  16. Mintz GS, Nissen SE, Anderson WD, et al. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-1492.[Free Full Text]
  17. Meredith IT, Ormiston J, Whitbourn R, et al. First-in-human study of the Endeavor ABT-578-eluting phosphorylcholine-encapsulated stent system in de novo native coronary lesions: Endeavor I Trial EuroInterv 2005;1:157-164.
  18. Fajadet J, Wijns W, Laarman G-J, et al. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial Circulation 2006;114:798-806.[Abstract/Free Full Text]
  19. Kandzari DE, Leon MB, Popma JJ, et al. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial J Am Coll Cardiol 2006;48:2440-2447.[Abstract/Free Full Text]
  20. Leon MB, Mauri L, Popma JJ, et al. A randomized comparison of the Endeavor zotarolimus-eluting stent versus the Taxus paclitaxel-eluting stent in de novo native coronary lesions: 12-month outcomes from the ENDEAVOR IV trial J Am Coll Cardiol 2009In press.
  21. Mauri L, Cutlip DE, Leon MB, et al. Long-term safety results from the Endeavor program: four-year follow-up [TCT abstract 305] Am J Cardiol 2008;108(Suppl 1)124i.
  22. Cutlip DE, Windecker S, Mehran R, et al. Clinical end points in coronary stent trials: a case for standardized definitions Circulation 2007;115:2344-2351.[Abstract/Free Full Text]
  23. O'Malley AJ, Normand SL, Kuntz RE. Application of models for multivariate mixed outcomes to medical device trials: coronary artery stenting Stat Med 2003;22:313-336.[CrossRef][Web of Science][Medline]
  24. Morice M-C, Serruys PW, Sousa E, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization N Engl J Med 2002;346:1773-1780.[CrossRef][Web of Science][Medline]
  25. Tsuchida K, Piek JJ, Neumann F-J, et al. One-year results of a durable polymer everolimus-eluting stent in de novo coronary narrowings (The SPIRIT FIRST Trial) EuroInterv 2005;1:266-272.
  26. Grube E, Silber S, Hauptmann KE, et al. TAXUS I: six- and twelve-month results from a randomized, double-blind trial of a slow-release paclitaxel-eluting stent for de novo coronary lesions Circulation 2003;107:38-42.[Abstract/Free Full Text]
  27. Grube E, Sonoda S, Ikeno F, et al. Six- and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer Circulation 2004;109:2168-2171.[Abstract/Free Full Text]
  28. Mauri L, Orav EJ, O'Malley J, et al. Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents Circulation 2005;111:321-327.[Abstract/Free Full Text]
  29. Feres F, Costa JR, Abizaid A. Very late thrombosis after drug-eluting stents Catheter Cardiovasc Interv 2006;68:83-88.[CrossRef][Web of Science][Medline]

Related Article

A Generation 2.5 Drug-Eluting Stent?
Stephen G. Ellis
J. Am. Coll. Cardiol. Intv. 2009 2: 986-988. [Full Text] [PDF]



This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
B. C. Brott
Linking Drug-Eluting Stent Kinetics and Clinical Outcomes: Insights From Optical Coherence Tomography
J. Am. Coll. Cardiol. Intv., July 1, 2011; 4(7): 786 - 788.
[Full Text] [PDF]


Home page
Circ Cardiovasc IntervHome page
K. Waseda, J. Ako, M. Yamasaki, T. Koizumi, R. Sakurai, Y. Hongo, B.-K. Koo, J. Ormiston, S. G. Worthley, R. J. Whitbourn, et al.
Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers: Insights From the RESOLUTE Trial
Circ Cardiovasc Interv, June 1, 2011; 4(3): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. C. Yeung, M. B. Leon, A. Jain, T. R. Tolleson, D. J. Spriggs, B. T. Mc Laurin, J. J. Popma, P. J. Fitzgerald, D. E. Cutlip, J. M. Massaro, et al.
Clinical Evaluation of the Resolute Zotarolimus-Eluting Coronary Stent System in the Treatment of De Novo Lesions in Native Coronary Arteries: The RESOLUTE US Clinical Trial
J. Am. Coll. Cardiol., April 26, 2011; 57(17): 1778 - 1783.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Garg and P. W. Serruys
Coronary Stents: Looking Forward
J. Am. Coll. Cardiol., August 31, 2010; 56(10_Suppl_S): S43 - S78.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
S. G. Ellis
A Generation 2.5 Drug-Eluting Stent?
J. Am. Coll. Cardiol. Intv., October 1, 2009; 2(10): 986 - 988.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meredith, I. T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Meredith, I. T.
Related Collections
Right arrowRelated Article

Advertisement
 
   
 
home link current link search link archive link topics link cardiology careers link